ExoAir® 130
Brand: Tremco IncorporatedExoAir® 130 Fluid-Applied Synthetic Air and Vapor Barrier Membrane is a monolithic, elastomeric membrane designed to seal exterior above-grade wall assemblies and mitigate air infiltration/exfiltration, vapor transmission and water penetration. It is available in a single grade that can be roller or spray applied using the appropriate spraying equipment.
Features- EXOAIR 130 is a seamless, monolithic membrane that creates a fully adhered air and vapor barrier when properly installed
- The ability to roller or spray apply the material affords the contractor the ability to accelerate installation times compared to traditional selfadhered membrane systems
- EXOAIR 130 is formulated for UV resistance providing the flexibility to install rain screen systems with open joints or to allow the membrane to be exposed longer during the construction process
- EXOAIR 130 is specifically formulated for design option
Specifications
Brand
Type
- Synthetic Acrylic
Color
- White
Solids
- 56%
Cure Time
- 16 to 24 hr at 75°F (24°C), 50% RH
Application
- Sprayer/Roller
Thickness
- 40 mils (dry)
- Minimum 70 mils (wet)
Storage Temperature
- 40 to 100°F (5 to 37°C)
Application Temperature
- Above 40 °F (5 °C) and rising. If installing below 40 °F (5 °C), please refer to Cold Weather Air Barrier Installation Technical Bulletin
Service Temperature
- Intermittent Exposure up to 240° (115°)
Maximum V.O.C. (Method 310)
- 19 g/L
Hydrostatic Head (AATCC - 127)
- Pass
Crack Bridging (ASTM C1305)
- Pass
Elongation (ASTM D412)
- 346%
Water Immersion (ASTM D870)
- Pass
Adhesion (ASTM D4541)
- Exterior Sheathing: 16 PSI
- Concrete: 60 PSI
Antifungal (ASTM D5590)
- Pass
Water Vapor Permeance (ASTM E96 Dry Cup)
- <0.1 US Perm
Water Vapor Permeance (ASTM E96 Wet Cup)
- 0.727 Perms
Water Penetration (ASTM E331)
- Passed at 6.27 lb/ft² (300 Pa) for 2 hours
- Passed at 2.86 lb/ft² (137 Pa) for 15 mins
Cone Calorimeter (ASTM E1354)
- Data for EJ Analysis
Air Leakage of Material (ASTM E2178; Free Film Method @ 75 Pa)
- 0.0001 cfm/ft² (0.0005 L/sm²)
Air Leakage of Assembly (ASTM E2357)
- 0.002 cfm/ft² (0.009 L/sm²)
Fire Resistance of Assembly (NFPA 285)
- Pass
Flame Spread (ASTM E84)
- 15
Smoke Development (ASTM E84)
- 25