Type
- Polymer-Modified Emulsion
Thickness
- 36 mils (dry to represent actual dry film thickness)
- Minimum 60 mils (wet)
Cure Time
- 16 to 24 hr at 75°F (24°C), 50% RH
Application Temperature
- If installing below 40°F (5°C), refer to Cold Weather Air Barrier Installation Technical Bulletin
- Above 40°F (5°C) and rising
Service temperature
- Intermittent Exposure up to 158°F (70°C)
Maximum V.O.C. (Method 310)
Crack Bridging (ASTM C1305)
Elongation (ASTM D412 Die C)
Tensile Strength (ASTM D412 Die C)
Adhesion (ASTM D4541)
- Exterior Sheathing: 19 PSI
- Concrete: 28 PSI
Water Penetration (ASTM E331)
- Passed at 12 lb/ft² (575Pa)
Air Leakage of Material (ASTM E2178; Free Film Method @ 75 Pa)
- 0.0001 cfm/ft² (0.0006 L/(s•m²))
Air Leakage of Assembly (ASTM E2357)
- 0.002 cfm/ft² @ 1.56 lb/ft² (0.012 L/ (s•m²) @ (75 Pa))
Water Vapor Transmission (ASTM E96 Wet Cup)