Planters (PUMA)

Brand: Tremco Incorporated

TREMproof® PUMA Planters System is a cold-applied, waterproofing system that is based on polyurethane-methacrylate (PUMA) technology. PUMA waterproofing systems offer superior elongation over traditional MMA/PMMA technology systems. TREMproof PUMA Planters System is composed of a primer (Tremco PUMA Primer or TREMprime VB Primer) and a base coat (Tremco PUMA BC or BC LM) Tremco PUMA TC can be used if UV protection is required. All system components, except TREMprime VB, are cured using Tremco PUMA Initiator or Initiator+.
Features
  • TREMproof PUMA is a cold-applied system designed for waterproofing concrete slabs and protecting occupied areas underneath from water damage.
  • This waterproofing system is ideal for planters.
  • PUMA technology delivers extreme durability while maintaining its crack-bridging characteristics, eliminating the need for reinforcing fabric
  • Inhibits root penetration when installed at or greater than minimum recommended thickness
  • Rapid set-up times allow for quick overall installation, as well as the ability to open up to foot traffic one hour later
  • Can be applied at temperatures as low as 14 °F (-10 °C), which allows for continuation of projects in the colder months
  • Unique chemistry allows for easy repair
  • Zero Volatile Organic Compounds (VOCs)
  • Compatible with Tremco sealants, coatings and expansion joints, which is essential for tie-ins, detailing and penetrations

Specifications

VOC Content (Method 310)

  • 0 g/L

% Solids (By Weight) (ASTM D1353)

  • 100%

Drying Time @ 75°F, 50% RH (ASTM D1640)

  • PUMA BC - 80 mil film, 1 hr
  • Puma TC - 17 mil film, 1 hr

Weathering (ASTM D822) Weatherometer (350 hr)

  • PUMA BC - N/A
  • PUMA TC - No Effect

Elongation (ASTM D638)

  • PUMA BC - 407-420%
  • PUMA TC - 130%

Elongation (ASTM D5147)

  • Min 30%

Tensile Strength (ASTM D638 @ 75°F)

  • PUMA BC - 991-1680 PSI
  • PUMA TC - 986 PSI

Tearing Resistance (ASTM D4073)

  • PUMA BC - 91 lbf
  • PUMA TC - 203 lbf

Hardness, Shore D (ASTM D2240)

  • PUMA BC - 18-35
  • PUMA TC - 55

Hardness, Shore A (ASTM D2240)

  • PUMA TC - 100
  • PUMA BC - 65-87

Abrasion Resistance (1000 Cycles) (ASTM D4060)

  • PUMA TC - 51 mg
  • PUMA BC - N/A

Low-Temperature Crack Bridging (ASTM C1305)

  • PUMA TC - N/A
  • PUMA BC - Passes

Taber Abrasion (ASTM C501)

  • PUMA BC - Passes
  • PUMA TC - N/A

Peak Load @ 73°F, AVG (ASTM D5147)

  • PUMA BC - >70 lbf/in
  • PUMA TC - 238 lb/in

Puncture Resistance (ASTM D5602)

  • >56 lbs

Water Absorption (ASTM D570)

  • <0.1%

Water Vapor Transmission (ASTM E96)

  • 0.03 perms

Adhesion-In-Peel (ASTM C794)

  • PUMA BC - Concrete Failure with Primer
  • PUMA TC - N/A

Self-Ignition Temperature (ASTM D1929)

  • PUMA BC - 800°F (427°C)
  • PUMA TC - 850°F (454°C)

Smoke Density (ASTM D2843)

  • PUMA BC - 4.1%
  • PUMA TC - 2.1%

Rate of Burn (ASTM D635)

  • PUMA BC - 1.2 in/min
  • PUMA TC - 0.2 in/min

Documentation